SC6000 HOST MODE PROGRAMMING
36
4
PARAMETER COMPLETE PATH SHC PT VALUE
EAN/UPC
ADD ON 5
/Layout/SlvPar/CodPar
/AddOn5
149 1 0 = Disable
1 = Enable
CODE 3 OF 9 PARAMETERS
Decoding Severity /Layout/SlvPar/CodPar
/Code39Par/DecSev
161 0 Range: 1 to 5
Check Digit /Layout/SlvPar/CodPar
/Code39Par/ChkDgt
162 1 0 = Disable
1 = Enable
Length Type /Layout/SlvPar/CodPar
/Code39Par/Lentyp
180 1 0 = Variable
1 = Fixed
CODE 3 OF 9 FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length /Layout/SlvPar/CodPar
/Code39Par/Digit#N
163 0 Range: 0 to 50
CODE 2 OF 5 INTERLEAVED PARAMETERS
Decoding Severity /Layout/SlvPar/CodPar
/Code25Par/DecSev
164 0 Range: 1 to 5
Check Digit /Layout/SlvPar/CodPar
/Code25Par/ChkDgt
165 1 0 = Disable
1 = Enable
Length Type /Layout/SlvPar/CodPar
/Code25Par/Lentyp
181 1 0 = Variable
1 = Fixed
CODE2 OF 5 INTERLEAVED FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length /Layout/SlvPar/CodPar
/Code25Par/Digit#N
166 0 Range: 0 to 50
CODE 2 OF 5 COMPRESSED PARAMETERS
Decoding Severity /Layout/SlvPar/CodPar
/Code25CmpPar
/DecSev
167 0 Range: 1 to 5
Check Digit /Layout/SlvPar/CodPar
/Code25CmpPar/ChkDgt
168 1 0 = Disable
1 = Enable
Length Type /Layout/SlvPar/CodPar
/Code25CmpPar/Lentyp
182 1 0 = Variable
1 = Fixed
CODE2 OF 5 COMPRESSED FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length /Layout/SlvPar/CodPar
/Code25CmpPar/Digit#N
169 0 Range: 0 to 50
CODABAR PARAMETERS
Check Digit /Layout/SlvPar/CodPar
/CodBarPar/ChkDgt
170 1 0 = Disable
1 = Enable
Length Type /Layout/SlvPar/CodPar
/CodBarPar/Lentyp
183 1 0 = Variable
1 = Fixed
CODABAR FIXED LENGTH #N (DEPTH: N = 1 to 12)
Fixed Length /Layout/SlvPar/CodPar
/CodBarPar/Digit#N
171 0 Range: 0 to 50
CODE 93 PARAMETERS