SC6000 HOST MODE PROGRAMMING
30
4
PARAMETER COMPLETE PATH SHC PT VALUE
Protocol Index
Request Message
/Operating
/ProtocolIndexParameters
/MainPar/PIReqMsgMain
- 3 Length: 0 to 32
Distance from
Protocol Index to
Trigger Line (mm)
/Operating
/ProtocolIndexParameters
/MainPar/TxPtFromRef_main
- 0 Range:0 to 65532
PROTOCOL INDEX PARAMETERS / MODEM
Use Modem Serial
Port
/Operating
/ProtocolIndexParameters
/ModemPar/ModemEn
- 1 0 = Disable
1 = Enable Without
Request Message
2 = Enable With
Request Message
Header /Operating
/ProtocolIndexParameters
/ModemPar/StrModem
- 3 Length: 0 to 1
Terminator /Operating
/ProtocolIndexParameters
/ModemPar/StpModem
- 3 Length: 0 to 1
Protocol Index
Length
/Operating
/ProtocolIndexParameters
/ModemPar/PILengthModem
- 1 0 = Length In
Message
1 = Variable length
3 = 3
4 = 4
5 = 5
12 = 12
No Index Char /Operating
/ProtocolIndexParameters
/ModemPar
/NOIndexCharModem
- 3 Length: 0 to 1
Protocol Index
Request Message
/Operating
/ProtocolIndexParameters
/ModemPar
/PIReqMsgModem
- 3 Length: 0 to 32
Distance from
Protocol Index to
Trigger Line (mm)
/Operating
/ProtocolIndexParameters
/ModemPar/
/TxPtFromRef_modem
- 0 Range:0 to 65532
PROTOCOL INDEX PARAM. / ETH1 / PIUSERSOCKET #N (DEPTH: N = 1 to 3)
Use Socket /Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/SockEn
- 1 0 = Disable
1 = Enable Without
Request Message
2 = Enable With
Request Message
Header /Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/StrSock
- 3 Length: 0 to 1