SC6000 HOST MODE PROGRAMMING
26
4
PARAMETER COMPLETE PATH SHC PT VALUE
Serial Stop String /Operating
/SerialStop
87 3 Length: 1 to 32
Stop Input Number /Operating
/ONLStopIn
76 1 1 = PS
3 = PSAUX
4 = Input_1
5 = Input_2
6 = Input_3
Stop Input Active
Level
/Operating
/ONLStopInLev
77 1 0 = Active Closed
1 = Active Open
Stop Phase Edge /Operating
/PhaseOffLeadEdge
- 1 0 = Trailing
1 = Leading
Reading Phase
Timeout
/Operating
/OnLTimOutEn
78 1 0 = Disable
1 = Enable
Timeout (ms) /Operating
/ONLTimeOut
79 0 Range: 40 to 15000
Timeout Counting
From
/Operating
/ONLToutStart
- 1 0 = Start
1 = Stop
Stop Priority /Operating
/ONLStopPrio
80 1 0 = Input / SerialStop
1 = Always Timeout
Continuous
Threshold (number
of scans)
/Operating
/ContThreshold
- 0 Range: 10 to 32765
Physical Encoder /Operating
/PhyEnc
200 1 0 = Disable
1 = Enable
Encoder Step
(hundredths of
millimeter)
/Operating
/EncStep
201 0 Range: 1 to 10000
Conveyor Speed
(mm/sec)
/Operating
/PktrSpeed
216 0 Range: 50 to 10000
PS Line (mm) /Operating
/PktrPsLine
202 0 Range: -32767 to 32767y
Presence Sensor
Input
/Operating
/PktrPsIn
203 1 1 = PS
3 = PSAUX
4 = Input_1
5 = Input_2
6 = Input_3
Presence Sensor
Input Level
/Operating
/PktrPsLev
204 1 0 = Active Closed
1 = Active Open
Distance from PS
Line to TX Line (mm)
/Operating
/PktrTxLineDist
205 0 Range: 100 to 20000
Transmission Edge /Operating
/PktrTxLineEdge
206 1 0 = Leading
1 = Trailing
Max Number of
Packs
/Operating
/PktrMaxPacks
207 0 Range: 2 to 40
Minimum Distance
Error Behaviour
/Operating
/PktrMinDistEn
211 1 0 = Ignore Error
1 = Compose
2 = Discard Last
Minimum Distance
Between Packs
(mm)
/Operating
/PktrMinDist
208 0 Range: 10 to 10000
Minimum Pack
Length Error
Behaviour
/Operating
/PktrMinLenEn
212 1 0 = Ignore Error