DS1100
24
5
5 TECHNICAL FEATURES
DS1100-1XXX DS1100-2XXX
ELECTRICAL FEATURES
Power
Maximum input voltage 5 Vdc ± 5%
Power consumption max. 1.5 W
Serial Interfaces
Main RS485 half-duplex
Auxiliary RS232
Baud Rates 150 to 115200 baud
Inputs
External Trigger; IN1
Outputs
User-defined OUT1 and OUT2
V
CE
max. 50 Vdc
Collector current max. 50 mA continuous
V
CE
saturation
0.3V at 10 mA max.
Power dissipation max.
200 mW at 40 °C (Ambient temp.)
OPTICAL FEATURES
Light source Semiconductor laser diode
Wave length
(Note 1)
630 680 nm
Safety class Class 2 - IEC 825-1;
Class II - CDRH
READING FEATURES
(Note 2)
Scan rate 350 scans/sec
Aperture angle 70°
Max. Reading distance 220 mm, (8.7 in) 110 mm (4.3 in)
Maximum resolution 0.20 mm (8 mils) 0.12 mm (5 mils)
USER INTERFACE
LED indicators Power On,
Good Read,
Ext Trig,
TX Data,
Laser On