2
2.3.4 Inputs
The inputs available on the connector supplied with the scanner are indicated below:
Pin Name Function
18 IN1 - input 1 -
19 EXT TRIG- external trigger -
12, 22 GND I/O reference
The EXT TRIG input is used to connect the external trigger which tells the scanner to
scan for a code. The active state of this input is selected in software. Refer to the
Winhost Help On Line.
The yellow LED (Figure A, 5) is on when EXT TRIG- is shorted to GND.
This input is driven by an NPN type command. The connections are indicated in the
following diagram:
13/9
19
VS
EXT TRIG -
12/22
GND
EXTERNAL TRIGGER
Ground
V
DS1100
Signal
+ 5 V
47 K
Figure 9 - External Trigger Input command
The general purpose input IN1, in the Standard Application Program, can be used to
store the code verifier (see “Store Verifier Hw” in the WinHost Help On Line).
13/9
18
VS
IN1 -
12/22
GND
USER INTERFACE
Ground
V
DS1100
+ 5 V
47 K
Figure 10 - IN1 - Input command