2
2.3.3 Auxiliary Interface - RS232
The auxiliary serial interface is used exclusively for RS232 point-to-point
connections. It is also used for configuring the DS1100.
The parameters relative to the auxiliary interface (baud rate, data bits, etc.) can be
defined using the Winhost utility program or "Host Mode Programming", installed
from the diskette.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary
interface:
Pin Name Function
3, 20 RXAUX received data
2, 21 TXAUX transmitted data
7 SGND signal ground
3/20
2/21
7
SGND
USER INTERFACE
DS1100
RXD
TXD
SGND
TXAUX
RXAUX
Figure 8 - RS232 auxiliary interface connections