BHS AND REDS INSTALLATION MANUAL
REDS Additional Frame Kit Bill Of Materials:
Bosch Profile 45x45L L = 388 mm
Bosch Profile 45x45L L = 580 mm
Bosch Bracket 45x180 for foundation mounting
Bosch Angular Bracket 45x45
Bosch Profile 45x45L L = 200 mm
Bosch Profile 45x45L L = 1400 mm
T-bolts M8x25 for frame and scanner mounting
T-nuts M8 for frame and scanner mounting
6.2.2 Additional REDS Devices and Parts
In addition to the devices provided in the Standard BHS kit, the following parts are necessary
to construct the redundancy station:
SC6000-1200 Universal Controller, Ethernet
J-box power unit 110/230 VAC 24 V 480 W
25p cable SC6000 to PWO PWR/NET, 3 m
(for Power/Net connections)
25p cable SC6000 to PWO I/O, 3 m
(for Extended I/O connections)
9p cable SC6000 to PWO, 3 m
(for serial connections if used)
17p cable PWO to PWO, 3 m (for redundancy)
Bus terminator kit (5 pcs)
Photocell kit - PNP (PH-1)
Optical Encoder (10 m Cable + Spring)
6.2.3 Presence Sensor Mounting
Both photocells must give to the controllers the same information at the same time, so some
precautions must be taken:
The photocells must detect the same number of objects.
The photocells must detect the same length of the object.
If it is possible, avoid mounting the photocells at the beginning of the conveyor belt
because the packages usually jump passing from one belt to the other.
There are two possibilities to connect the two photocells.