GWY-01-DNT-01 MANUAL – REV. 02 CHAPTER 4:
COMMAND MAPPING
PAGE 38 OF 67
4.5.4 CBx - Gateway Response Example
Below is the Gateway response to the command “Get Node Status List” (as issued in
the previous example).
WORD DESCRIPTION MSB LSB
01 Overall Length of Response (in “words,” not
including the previous 2-bytes – CBx Header and
Node ID Echo)
0x00 0x0E
02 0xAA in MSB
Command Echo in LSB: (0x13)
0xAA 0x13
03 Instance Counter in MSB
Node ID Echo in LSB (0x20 = Gateway Node 32)
<IC> 0x20
04 Month and Day Timestamp (March 19th)
0x03 0x13
05 Hour and Minute Timestamp (10:11: AM)
0x0A 0x0B
06 Seconds Timestamp in MSB: (36 seconds)
Additional Data Length in LSB: (16 bytes)
0x24 0x10
07 Status of Node ID 1 and 2
0x00 0x00
08 Status of Node ID 3 and 4
0x04 0x00
09 Status of Node ID 5 and 6
0x00 0x04
0A Status of Node ID 7 and 8
0x00 0x00
0B Status of Node ID 9 and 10
0x00 0x00
0C Status of Node ID 11 and 12
0x00 0x00
0D Status of Node ID 13 and 14
0x00 0x00
0E Status of Node ID 15 and 16
0x00 0x00
In the above example, the Node Status Byte “0x04” (meaning “Controller Healthy”)
was reported for Nodes 03 and 06, indicating that the Gateway recognizes
functioning RFID controllers at Node 03 and Node 06. (See the Node Status Byte
Definition Table below for more information).