Datalogic GWY-01-PBS-01 Dokumentacja Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 67
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 17
GWY-01-DNT-01 MANUAL – REV. 02 CHAPTER 2:
GATEWAY OVERVIEW
PAGE 18 OF 67
2.2 LED INDICATORS
The Gateway has four LED indicators located on the front panel of the unit. The
LEDs display everything from bus and DeviceNet activity, to diagnostic information
and power status.
2.2.1 Front Panel LEDs
LED NAME LED COLOR DESCRIPTION
PWR
Green
The PWR (power) LED will light and remain
ON while power is applied to the Gateway.
BUS
Amber
The BUS LED will flash ON and OFF to
indicate that data is being transmitted
between the Gateway and one or more RFID
controllers.
DEVICENET
Amber
For the DEVICENET LED description, see
table below.
ERR
Red
The ERR (error) LED will turn ON when the
Gateway experiences an error condition.
This LED will be cleared when the next valid
command is received by the Gateway.
Table 2-1: Front Panel LEDs
The table below describes the behavior of the DeviceNet LED indicator.
DEVICENET LED IS: INDICATES:
Off
Gateway is not online or not powered
Solid Green
Gateway is operational, online AND a connection is
established
Flashing Green
Gateway is operational and online, but with no established
I/O connections (idle on the network) or Gateway is online
and needs commissioning
Flashing Red
Recoverable fault detected and/or the Gateway’s I/O
connection timed out
Solid Red
Unrecoverable fault detected (for example, a duplicate node
address was encountered rendering Gateway unable to
communicate)
Table 2-2: DeviceNet LED Behavior