Symbologies
214 QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
MSI — cont.
MSI Check Character Transmission
Enables/disables transmission of an MSI check character.
MSI Length Control
This feature specifies either variable length decoding or fixed length decoding for the MSI sym-
bology.
Variable Length—
For variable length decoding, a minimum and maximum length may be set.
Fixed Length—
For fixed length decoding, two different lengths may be set.
$CMSCT00
MSI Check Character Transmission = Disable
$CMSCT01
MSI Check Character Transmission = Enable
DEFAULT
$CMSLC00
MSI Length Control = Variable Length
$CMSLC01
MSI = Fixed Length
DEFAULT