Symbologies
136 QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
Code 39 — cont.
Code 39 Set Length 2
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the
maximum label length if in
Variable Length Mode, or the second fixed length if in Fixed
Length
Mode. Length includes the bar codes check, data, and full-ASCII shift characters. The
length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See
Set Length 2 on page 269 for more detailed programming
instructions.
$CC3L2
Select Code 39Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters