Datalogic POWERSCAN 7000 2D Imager Instrukcja Obsługi Strona 1

Przeglądaj online lub pobierz Instrukcja Obsługi dla Czytniki kodów kreskowych Datalogic POWERSCAN 7000 2D Imager. Datalogic POWERSCAN 7000 2D Imager Programming instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 252
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Product Reference Guide

PowerScan® 7000 SRIProduct Reference Guide

Strona 2

Getting Started1-4 PowerScan® 7000 SRIWand Emulation Connection — Connect the scanner to the appro-priated port on the terminal/PC using the correct c

Strona 3 - Table of Contents

Symbologies5-2 PowerScan® 7000 SRIUPC-AThe following options apply to the UPC-A symbology.Disable/Enable UPC-AWhen disabled, the scanner will not read

Strona 4 - PowerScan® 7000 SRI

UPC-AProduct Reference Guide 5-3UPC-A — continuedSTARTSTATE BAR CODEDisable UPC-AEnable UPC-ADon’t Send Check DigitSendCheck DigitDon’t Expand to EAN-

Strona 5 - Product Reference Guide 1-iii

Symbologies5-4 PowerScan® 7000 SRIUPC-A — continuedSTARTSTATE BAR CODEDisable Sys-tem Number TransmissionEnable System Number Trans-missionEND

Strona 6

UPC-AProduct Reference Guide 5-5UPC-A — continuedUPC-A Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-A label must

Strona 7 - Getting Started

Symbologies5-6 PowerScan® 7000 SRIUPC-A — continuedIn-store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store pr

Strona 8 - Connecting the Scanner

UPC-AProduct Reference Guide 5-7UPC-A — continuedAdd-On TimerThis feature sets the period of time after a UPC-A label is decoded when optional add-on

Strona 9 - Reference

Symbologies5-8 PowerScan® 7000 SRIUPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled, the scanner will not read

Strona 10 - Defaults

UPC-EProduct Reference Guide 5-9UPC-E — continuedSTARTSTATE BAR CODEDisable UPC-EEnable UPC-EDon’t Send Check DigitSendCheck DigitExclude Sys-tem Numb

Strona 11 - General Features

Symbologies5-10 PowerScan® 7000 SRIDon’t Expand UPC-E toUPC-AExpand UPC-E to UPC-ADon’t Expand UPC-E toEAN-13Expand UPC-E to EAN-13ENDUPC-E — continue

Strona 12 - 2-2 PowerScan® 7000 SRI

UPC-EProduct Reference Guide 5-11UPC-E — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be de

Strona 13 - Powerdown Timeout

Product Reference Guide 2-1Chapter 2General FeaturesDouble Read TimeoutThe Double Read Timeout feature sets a time limit that determines how much time

Strona 14 - Powerdown Timeout — continued

Symbologies5-12 PowerScan® 7000 SRIGTINThe following options apply to the GTIN label data format.Disable/Enable GTINWhen this feature is enabled, the

Strona 15 - LED and Beeper Indicators

EAN-13Product Reference Guide 5-13EAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disabled, the scanner will not r

Strona 16 - LED Idle State

Symbologies5-14 PowerScan® 7000 SRIEAN-13 — continuedSTARTSTATE BAR CODEDisable EAN-13Enable EAN-13Don’t Send Check DigitSendCheck DigitDon’t Transmit

Strona 17 - Good Read: When to Indicate

EAN-13Product Reference Guide 5-15Disable ISBNEnable ISBNENDEAN-13 — continuedSTARTSTATE BAR CODE

Strona 18 - Good Read Beep Control

Symbologies5-16 PowerScan® 7000 SRIEAN-13 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-13 label must

Strona 19 - Good Read Beep Frequency

EAN-8Product Reference Guide 5-17EAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read

Strona 20 - Good Read Beep Length

Symbologies5-18 PowerScan® 7000 SRIEAN-8 — continuedExpand EAN-8 to EAN-13 — Expands EAN-8 data to the EAN-13 data format. Selecting this feature also

Strona 21 - Product Reference Guide 2-11

EAN-8Product Reference Guide 5-19EAN-8 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-8 label must be d

Strona 22 - Good Read Beep Volume

Symbologies5-20 PowerScan® 7000 SRIAdd-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will re

Strona 23 - Scanning Features

Add-onsProduct Reference Guide 5-21Add-ons — continuedSTARTSTATE BAR CODEDisable Optional 2-Digit Add-onsEnable Optional 2-Digit Add-onsDisable Option

Strona 24 - Scan Mode — continued

General Features2-2 PowerScan® 7000 SRIDouble Read Timeout — continuedSTARTDURATION BAR CODE0.5 Second0.6 Second0.7 Second0.8 Second0.9 Second1 Second

Strona 25 - Active Scanning Time

Symbologies5-22 PowerScan® 7000 SRIRSS-14The following options apply to the RSS-14 symbology.Disable/Enable RSS-14When this feature is disabled, the s

Strona 26 - 2-16 PowerScan® 7000 SRI

RSS-14Product Reference Guide 5-23RSS-14 — continuedSTARTSTATE BAR CODEDisableRSS-14Enable RSS-14DisableUCC/EAN 128 EmulationEnableUCC/EAN 128 Emulati

Strona 27 - Laser Pointer Control

Symbologies5-24 PowerScan® 7000 SRIRSS-14 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS-14 label must

Strona 28 - 2-18 PowerScan® 7000 SRI

RSS-14Product Reference Guide 5-25RSS-14 — continuedRSS-14 2D ComponentThis feature controls the requirement that a 2D label component be decoded when

Strona 29 - Product Reference Guide 2-19

Symbologies5-26 PowerScan® 7000 SRIRSS ExpandedThe following options apply to the RSS Expanded symbology.Disable/Enable RSS ExpandedWhen this feature

Strona 30

RSS ExpandedProduct Reference Guide 5-27RSS Expanded — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scann

Strona 31 - Features

Symbologies5-28 PowerScan® 7000 SRIRSS Expanded — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 32

RSS ExpandedProduct Reference Guide 5-29RSS Expanded — continuedRSS Expanded Length 1, Length 2 Pro-gramming Instructions1. Scan the START bar code.2.

Strona 33 - Product Reference Guide 3-3

Symbologies5-30 PowerScan® 7000 SRIRSS Expanded — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS Expanded

Strona 34 - Interface Selection

RSS ExpandedProduct Reference Guide 5-31RSS Expanded — continuedRSS Expanded 2D ComponentThis feature controls the requirement that a 2D label compone

Strona 35 - Interface Selection — cont

Powerdown TimeoutProduct Reference Guide 2-3Powerdown TimeoutThe Powerdown Timeout feature sets the time for automatically switching the unit off when

Strona 36

Symbologies5-32 PowerScan® 7000 SRIRSS LimitedThe following options apply to the RSS Limited symbology.Disable/Enable RSS LimitedWhen this feature is

Strona 37

RSS LimitedProduct Reference Guide 5-33RSS Limited — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS Limit

Strona 38

Symbologies5-34 PowerScan® 7000 SRIRSS Limited — continuedRSS Limited 2D ComponentThis feature controls the requirement that a 2D label component be d

Strona 39 - Interface Features

Code 39Product Reference Guide 5-35Code 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When this feature is disabled, th

Strona 40 - RS-232 Interface Features

Symbologies5-36 PowerScan® 7000 SRICode 39 — continuedSTARTSTATE BAR CODEDisableCode 39EnableCode 39DisableCheck CharCalculationEnableCheck CharCalcul

Strona 41 - Product Reference Guide 3-11

Code 39Product Reference Guide 5-37Code 39 — continuedSTARTSTATE BAR CODEDon’t TransmitStart/Stop CharactersTransmitStart/Stop CharactersDisableCode 3

Strona 42 - 3-12 PowerScan® 7000 SRI

Symbologies5-38 PowerScan® 7000 SRICode 39 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Strona 43 - Product Reference Guide 3-13

Code 39Product Reference Guide 5-39Code 39 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 44 - Software Flow Control

Symbologies5-40 PowerScan® 7000 SRICode 39 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the Set Length 1 or Se

Strona 45 - Product Reference Guide 3-15

Code 39Product Reference Guide 5-41Code 39 — continuedQuiet ZonesThis feature enables/disables the requirement that quiet zones must be present for Co

Strona 46 - 3-16 PowerScan® 7000 SRI

General Features2-4 PowerScan® 7000 SRIPowerdown Timeout — continuedSTARTDURATION BAR CODE3 Minutes4 MinutesEND

Strona 47 - Product Reference Guide 3-17

Symbologies5-42 PowerScan® 7000 SRICode 39 — continuedCode 39 StitchingEnables/disables stitching for Code 39 labels. When parts of a Code 39 bar code

Strona 48 - RS-232 Invert

Code 39Product Reference Guide 5-43Code 39 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 39 label mus

Strona 49 - Product Reference Guide 3-19

Symbologies5-44 PowerScan® 7000 SRIPharmacode 39The following options apply to the Pharmacode 39 symbology.Disable/Enable Pharmacode 39When this featu

Strona 50 - 3-20 PowerScan® 7000 SRI

Pharmacode 39Product Reference Guide 5-45Pharmacode 39 — continuedStart/Stop CharactersEnables or disables transmission of Pharmacode 39 start/stop ch

Strona 51 - Beep on Not on File

Symbologies5-46 PowerScan® 7000 SRICode 128 and EAN 128The following options apply to the Code 128 and EAN 128 symbolo-gies.Code 128 — When this featu

Strona 52 - ACK NAK Options

Code 128 and EAN 128Product Reference Guide 5-47Code 128 and EAN 128 — continuedTransmit Function CharactersEnables/disables transmission of Code128 f

Strona 53 - ACK NAK Options — cont

Symbologies5-48 PowerScan® 7000 SRICode 128 and EAN 128 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the sc

Strona 54 - ACK Character

Code 128 and EAN 128Product Reference Guide 5-49Code 128 and EAN 128 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 55 - NAK Character

Symbologies5-50 PowerScan® 7000 SRICode 128 and EAN 128 — continuedCode 128 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. S

Strona 56 - Retry on ACK NAK Timeout

Code 128 and EAN 128Product Reference Guide 5-51Code 128 and EAN 128 — continuedCode 128 StitchingEnables/disables stitching for Code 128 labels. When

Strona 57 - ACK NAK Timeout Value

LED and Beeper IndicatorsProduct Reference Guide 2-5LED and Beeper IndicatorsPower On AlertDisables or enables the indication (from the Beeper) that t

Strona 58 - ACK NAK Retry Count

Symbologies5-52 PowerScan® 7000 SRICode 128 and EAN 128 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code

Strona 59 - ACK NAK Error Handling

Interleaved 2 of 5Product Reference Guide 5-53Interleaved 2 of 5The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbol-ogy.Disable/En

Strona 60 - 3-30 PowerScan® 7000 SRI

Symbologies5-54 PowerScan® 7000 SRIInterleaved 2 of 5 — continuedSTARTSTATE BAR CODEDisableInterleaved2 of 5EnableInterleaved2 of 5DisableCheck DigitC

Strona 61 - IBM-USB Interface Features

Interleaved 2 of 5Product Reference Guide 5-55Interleaved 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enable

Strona 62 - 3-32 PowerScan® 7000 SRI

Symbologies5-56 PowerScan® 7000 SRIInterleaved 2 of 5 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 63

Interleaved 2 of 5Product Reference Guide 5-57Interleaved 2 of 5 — continuedInterleaved 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the

Strona 64 - Wand Emulation — cont

Symbologies5-58 PowerScan® 7000 SRIInterleaved 2 of 5 — continuedInterleaved 2 of 5 StitchingEnables/disables stitching for Interleaved 2 of 5 labels.

Strona 65

Interleaved 2 of 5Product Reference Guide 5-59Interleaved 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive time

Strona 66

Symbologies5-60 PowerScan® 7000 SRICodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen this feature is disabled, th

Strona 67

CodabarProduct Reference Guide 5-61Codabar — continuedSTARTSTATE BAR CODEDisableCodabarEnableCodabarDisableCheck CharVerificationEnableCheck CharVerif

Strona 68

General Features2-6 PowerScan® 7000 SRILED Idle StateSpecifies state of scanner’s LED when the scanner is ready to read a bar code.STARTSTATE BAR CODE

Strona 69 - Symbology Conversion

Symbologies5-62 PowerScan® 7000 SRICodabar — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Strona 70 - Symbology Conversion — cont

CodabarProduct Reference Guide 5-63Codabar — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 71 - Keyboard Wedge/USB Keyboard

Symbologies5-64 PowerScan® 7000 SRICodabar — continuedCodabar Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the

Strona 72 - 3-42 PowerScan® 7000 SRI

CodabarProduct Reference Guide 5-65Codabar — continuedQuiet ZonesThis feature enable/disables the requirement that quiet zones must be present for Cod

Strona 73 - Product Reference Guide 3-43

Symbologies5-66 PowerScan® 7000 SRICodabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop patterns. Select one pair to match

Strona 74 - 3-44 PowerScan® 7000 SRI

CodabarProduct Reference Guide 5-67Codabar — continuedSTARTSTATE BAR CODEStart/Stop Type: ABCD/TN*EStart/Stop Type: ABCD/ABCDStart/Stop Type: abcd/tn*

Strona 75 - Product Reference Guide 3-45

Symbologies5-68 PowerScan® 7000 SRICodabar — continuedSTARTSTATE BAR CODEDisable Start/Stop Char MatchEnable Start/Stop Char MatchEND

Strona 76 - 3-46 PowerScan® 7000 SRI

CodabarProduct Reference Guide 5-69Codabar — continuedCodabar StitchingEnables/disables stitching for Codabar labels. When parts of a Codabar label ar

Strona 77 - Product Reference Guide 3-47

Symbologies5-70 PowerScan® 7000 SRICodabar — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Codabar label mus

Strona 78 - Set Wedge Quiet Inter

Code 93Product Reference Guide 5-71Code 93The following options apply to the Code 93 symbology.Disable/Enable Code 93When this feature is disabled, th

Strona 79 - Product Reference Guide 3-49

LED and Beeper IndicatorsProduct Reference Guide 2-7Good Read: When to IndicateThis feature specifies when the scanner will provide indication (beep a

Strona 80 - Interface Related Features

Symbologies5-72 PowerScan® 7000 SRICode 93 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Strona 81 - Data Editing

Code 93Product Reference Guide 5-73Code 93 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 82 - 00 - 20 Characters (ASCII)

Symbologies5-74 PowerScan® 7000 SRICode 93 — continuedCode 93 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the

Strona 83 - Appendix C

Code 93Product Reference Guide 5-75Code 93 — continuedCode 93 StitchingEnables/disables stitching for Code 93 bar codes. When parts of a Code 93 label

Strona 84 - Example: Setting a

Symbologies5-76 PowerScan® 7000 SRICode 93 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 93 label mus

Strona 85 - Product Reference Guide 4-5

Code 11Product Reference Guide 5-77Code 11The following options apply to the Code 11 symbology.Disable/Enable Code 11When this feature is disabled, th

Strona 86 - AIM ID — continued

Symbologies5-78 PowerScan® 7000 SRICode 11 — continuedNumber of Check CharactersSpecifies the number of Code 11 check characters (one or two) to be ca

Strona 87 - Label ID

Code 11Product Reference Guide 5-79Code 11 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Strona 88 - Label ID — continued

Symbologies5-80 PowerScan® 7000 SRICode 11 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Strona 89

Code 11Product Reference Guide 5-81Code 11 — continuedCode 11 Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan either

Strona 90

General Features2-8 PowerScan® 7000 SRIGood Read Beep ControlThis feature enables/disables the scanner’s ability to beep upon a success-ful decode of

Strona 91

Symbologies5-82 PowerScan® 7000 SRICode 11 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 11 label mus

Strona 92

MSI/PlesseyProduct Reference Guide 5-83MSI/PlesseyThe following options apply to the MSI/Plessey symbology.Disable/Enable MSI/PlesseyWhen this feature

Strona 93

Symbologies5-84 PowerScan® 7000 SRIMSI/Plessey — continuedSTARTSTATE BAR CODEDisableMSI/PlesseyEnableMSI/PlesseyDisableCheck DigitVerificationEnableCh

Strona 94

MSI/PlesseyProduct Reference Guide 5-85DisableCheck DigitTransmissionEnableCheck DigitTransmissionENDMSI/Plessey — continuedSTARTSTATE BAR CODE

Strona 95 - Case Conversion

Symbologies5-86 PowerScan® 7000 SRIMSI/Plessey — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner wil

Strona 96 - Character Conversion

MSI/PlesseyProduct Reference Guide 5-87MSI/Plessey — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 97 - Product Reference Guide 4-17

Symbologies5-88 PowerScan® 7000 SRIMSI/Plessey — continuedMSI/Plessey Length 1, Length 2 Program-ming Instructions1. Scan the START bar code.2. Scan e

Strona 98

MSI/PlesseyProduct Reference Guide 5-89MSI/Plessey — continuedMSI/Plessey StitchingEnables/disables stitching for MSI/Plessey bar codes. When parts of

Strona 99 - Symbologies

Symbologies5-90 PowerScan® 7000 SRIMSI/Plessey — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an MSI/Plessey l

Strona 100 - System Number Transmission

MSI/PlesseyProduct Reference Guide 5-91Standard 2 of 5The following options apply to the Standard 2 of 5 symbology.Disable/Enable Standard 2 of 5When

Strona 101 - UPC-A — continued

LED and Beeper IndicatorsProduct Reference Guide 2-9Good Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high fr

Strona 102

Symbologies5-92 PowerScan® 7000 SRIStandard 2 of 5 — continuedSTARTSTATE BAR CODEDisableStd 2 of 5EnableStd 2 of 5DisableCheck DigitVerificationEnable

Strona 103

MSI/PlesseyProduct Reference Guide 5-93Standard 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the sca

Strona 104

Symbologies5-94 PowerScan® 7000 SRIStandard 2 of 5 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 105

MSI/PlesseyProduct Reference Guide 5-95Standard 2 of 5 — continuedStandard 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the START bar co

Strona 106 - System Number

Symbologies5-96 PowerScan® 7000 SRIStandard 2 of 5 — continuedStandard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 bar codes. When

Strona 107 - UPC-E — continued

MSI/PlesseyProduct Reference Guide 5-97Standard 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a Stan-d

Strona 108

Symbologies5-98 PowerScan® 7000 SRIPDF 417The following options apply to the PDF 417 symbology.Disable/Enable PDF 417When this feature is disabled, th

Strona 109

PDF 417Product Reference Guide 5-99PDF 417 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Strona 110 - Disable/Enable GTIN

Symbologies5-100 PowerScan® 7000 SRIPDF 417 — continuedSTARTMODE BAR CODEVariable LengthDecodingFixed Length DecodingEND

Strona 111 - EAN-13 Flag 1 Character

PDF 417Product Reference Guide 5-101PDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either th

Strona 112 - EAN-13 — continued

Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No

Strona 113

General Features2-10 PowerScan® 7000 SRIGood Read Beep LengthSpecifies the duration of a good read beep.STARTLENGTH BAR CODE60msec80msec100msec120msec

Strona 114

Symbologies5-102 PowerScan® 7000 SRIPDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a PDF 417 label mus

Strona 115 - Disable/Enable EAN-8

Micro PDF 417Product Reference Guide 5-103Micro PDF 417The following options apply to the Micro PDF 417 symbology.Disable/Enable Micro PDF 417When thi

Strona 116 - EAN-8 — continued

Symbologies5-104 PowerScan® 7000 SRIMicro PDF 417 — continuedPDF 128 EmulationDepending upon the other configuration features listed below, this fea-t

Strona 117

Micro PDF 417Product Reference Guide 5-105Micro PDF 417 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the sc

Strona 118 - 5-20 PowerScan® 7000 SRI

Symbologies5-106 PowerScan® 7000 SRIMicro PDF 417 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Strona 119 - Add-ons — continued

Micro PDF 417Product Reference Guide 5-107Micro PDF 417 — continuedMicro PDF 417 Length 1, Length 2 Pro-gramming Instructions1. Scan the START/END bar

Strona 120 - UCC/EAN 128 Emulation

Symbologies5-108 PowerScan® 7000 SRIMicro PDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a Micro PDF 4

Strona 121 - RSS-14 — continued

Product Reference Guide A-1Appendix AProduct SpecificationsOptical and Read Performance ParametersParameter SpecificationScanning Width2” wide at 1”

Strona 122

A-2 PowerScan® 7000 SRIPhysical PropertiesElectrical ParametersParameter SpecificationDimensions (Typical):Height 7.5”/190 mmLength 4.5”/115 mmWidth

Strona 123

Environmental ParametersProduct Reference Guide A-3Environmental ParametersParameter SpecificationMechanical Shock50 drops from 6.5 feet (2 meters) to

Strona 124 - RSS Expanded

LED and Beeper IndicatorsProduct Reference Guide 2-11Good Read Beep Length — continuedSTARTLENGTH BAR CODE180msec200msecEND

Strona 125 - RSS Expanded — continued

A-4 PowerScan® 7000 SRINOTES

Strona 126

Product Reference Guide B-1Appendix BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)RS-232IBM Port 5B/9B/1712CTS34RTS5 RXD6TXD78VCC IN

Strona 127

Cable PinoutsB-2 PowerScan® 7000 SRIIBM USBUSB & USB KeyboardWand Emulation1234D -56D +78VIN9GND101234D -56D +78 VBUS_VIN9GND10123 WAND~45678 VCC_

Strona 128

Standard Cable Pinouts (Primary Interface Cables)Product Reference Guide B-3Keyboard Wedge12 KB_DATA3 AT_CLK4 KB_CLK56 AT_DATA78VCC_IN9GND10Pin 110 Po

Strona 129

Cable PinoutsB-4 PowerScan® 7000 SRINOTES

Strona 130 - RSS Limited

Product Reference Guide C-1Appendix CAlpha-Numeric PadABCDEF

Strona 131 - RSS Limited — continued

C-2 PowerScan® 7000 SRIAlpha-Numeric Pad1230987654

Strona 132

Product Reference Guide D-1Appendix DDefault SettingsStandard Feature DefaultsThe table immediately below lists the default settings for the standard

Strona 133 - Code 39 Full ASCII

D-2 PowerScan® 7000 SRIInterface Selection RS-232 Std.Interface as requiredIBM Default:IBM Port 9BWincor/Nixdorf Default: RS-232-WNKeyboard Wedge Defa

Strona 134 - Code 39 — continued

Standard Feature DefaultsProduct Reference Guide D-3RS-232 Invert Disable 3-18Beep on ASCII BEL Enable 3-21Beep on Not on File Enable 3-21ACK NAK Opti

Strona 135

General Features2-12 PowerScan® 7000 SRIGood Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable vo

Strona 136

D-4 PowerScan® 7000 SRIWand Emulation:Transmit Trailing Noise—Wand Emulation:Enable3-38Wand Emulation:Symbology Conver-sion—Wand Emulation:No Conversi

Strona 137

Standard Feature DefaultsProduct Reference Guide D-5UPC-A w/P2 Addon Label IDA 4-8UPC-A w/P5 Addon Label IDA 4-8UPC-A w/C128 Addon Label IDA 4-9UPC-E

Strona 138 - Instructions

D-6 PowerScan® 7000 SRIISBN Label ID IWincor/Nixdorf:‘A’4-10GTIN Label ID G 4-11GTIN w/P2 addon Label IDG2 4-11GTIN w/P5 addon Label IDG5 4-11GTIN w/C

Strona 139

Standard Feature DefaultsProduct Reference Guide D-7Code 93 Label ID &Wincor/Nixdorf:“L’4-13Code 11 Label ID CE 4-13MSI/Plessey Label ID @Wincor/N

Strona 140

D-8 PowerScan® 7000 SRICheck Digit Transmis-sionSend Check Digit5-8System NumberExclude Sys-tem Number5-8Expand UPC-E to UPC-ADon’t Expand5-8Expand UP

Strona 141

Standard Feature DefaultsProduct Reference Guide D-9Optional Code 128 Add-onsDisable 5-20Disable/Enable RSS-14Disable 5-22UCC/EAN 128 Emula-tionDisabl

Strona 142 - Pharmacode 39

D-10 PowerScan® 7000 SRIRSS Limited 2D Com-ponentDisable 5-34Disable/Enable Code 39Enable 5-35Code 39 Check Char-acter CalculationDisable 5-35Code 39

Strona 143 - Pharmacode 39 — continued

Standard Feature DefaultsProduct Reference Guide D-11Code 128 Transmit Function CharactersDon’tTransmit5-47Code 128Length ControlVariable Length5-48Co

Strona 144 - Code 128 and EAN 128

D-12 PowerScan® 7000 SRICodabar Length Con-trolVariable Length5-62Codabar Length 1 3 5-64Codabar Length 2 50 5-64Codabar Quiet ZonesDon’t Require5-65C

Strona 145 - Transmit Function Characters

Standard Feature DefaultsProduct Reference Guide D-13Code 11 Check Char-acter TransmitEnable 5-78Code 11 Length Con-trolVariable Length5-79Code 11 Len

Strona 146 - Length Control

Scanning FeaturesProduct Reference Guide 2-13Scanning FeaturesScan ModeSelects the scan operating mode for the scanner. Selections are:• Single — When

Strona 147 - Product Reference Guide 5-49

D-14 PowerScan® 7000 SRIStd 2 of 5 Length 2 50 5-95Standard 2 of 5 Stitch-ingDisable 5-96Std 2 of 5Minimum Reads1 5-97Disable/Enable PDF 417Disable 5-

Strona 148

Product Reference Guide E-1Appendix EKeyboard FunctionKey MappingsKeyboard Model Cross ReferenceTa bl e E - 2 summarizes the keyboard models, their d

Strona 149 - Code 128 Stitching

E-2 PowerScan® 7000 SRITable E-1. Keyboard Model Cross ReferenceModel Type I/F IDTrans-mission ProtocolScancodeSetFunc.KeyMap SupportUseCountryModePC/

Strona 150 - Minimum Reads

Keyboard Model Cross ReferenceProduct Reference Guide E-3Table E-2. Scanset 1 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Mak

Strona 151 - Interleaved 2 of 5

E-4 PowerScan® 7000 SRITable E-3. Scanset 2 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Make E0h 11h01 SOH ALT right Break E

Strona 152 - 5-54 PowerScan® 7000 SRI

Keyboard Model Cross ReferenceProduct Reference Guide E-5Table E-4. Scanset 3, 102-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT r

Strona 153

E-6 PowerScan® 7000 SRITable E-5. Scanset 3 122-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT Right Make 39h01 SOH ALT Right Brea

Strona 154 - 5-56 PowerScan® 7000 SRI

Keyboard Model Cross ReferenceProduct Reference Guide E-7Table E-6. Japanese DOS Function Key MapASCII value ASCII code Key Scancode00h NUL ALT right

Strona 155 - Product Reference Guide 5-57

E-8 PowerScan® 7000 SRITable E-7. NEC 9801-Key Function Key MapASCII value ASCII code Key Scancode00h NUL unused n/a01h SOH CR 1Ch02h STX CAPS LOCK O

Strona 156 - Interleaved 2 of 5 Stitching

Keyboard Model Cross ReferenceProduct Reference Guide E-9Table E-8. USB Keyboard Function Key Usage MapASCII Key Value Usage Name00 NUL ALT right Make

Strona 157

General Features2-14 PowerScan® 7000 SRIScan Mode — continuedSTARTMODE BAR CODESingleTriggerlessStandStand w/IllumEND

Strona 158 - Check Character Verification

E-10 PowerScan® 7000 SRINOTES

Strona 159 - Codabar — continued

Product Reference Guide F-1Appendix FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:If one of the above

Strona 160

F-2 PowerScan® 7000 SRINOTES

Strona 161

Product Reference Guide G-1Appendix GSample Symbols0 123456 78901234567890Code 1289 780330 290951BC321123456-9$123456UPC-ACode 128Code 39Code 93I

Strona 162

G-2 PowerScan® 7000 SRISample Symbols(01)00123456789012Car RegistrationPDF417RSS-140100123456789050RSS Expanded

Strona 163

Product Reference Guide H-1Appendix HBeeper/LEDIndicationsLED and Beep IndicationsINDICATION DESCRIPTION LED BEEPERPower-up BeepThe scanner is in the

Strona 164

H-2 PowerScan® 7000BT SRIScanner Active ModeThe scanner is active and ready to scan.The LED is lit steadily. (ONLY applicable if LED Idle State is &qu

Strona 165

LED and Beep IndicationsProduct Reference Guide H-3Label Pro-gramming Mode Accep-tance of Pro-grammingConfiguration option(s) have been successfully p

Strona 166

H-4 PowerScan® 7000BT SRIError CodesUpon startup, if the scanner sounds a long tone, this means the scanner has not passed its automatic Selftest and

Strona 167

Error CodesProduct Reference Guide H-5NOTES

Strona 168

Scanning FeaturesProduct Reference Guide 2-15Active Scanning TimeThis setting determines the amount of time the scanner continues to scan in triggerle

Strona 169 - Disable/Enable Code 93

H-6 PowerScan® 7000BT SRINOTES

Strona 170 - Code 93 — continued

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Strona 171

AustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688France and BeneluxDatalogic Scanning Sarl

Strona 172

General Features2-16 PowerScan® 7000 SRIActive Scanning Time — continuedSTARTDURATION BAR CODE2 Minutes3 Minutes4 MinutesEND

Strona 173

Scanning FeaturesProduct Reference Guide 2-17Laser Pointer ControlWhen the trigger is pressed and Scan Mode is set to Single, the laser pointer will b

Strona 174

General Features2-18 PowerScan® 7000 SRILaser Pointer Control — continuedSTARTDURATION BAR CODE0.5 Seconds0.6 Seconds0.8 Seconds1 Second1.2 Seconds1.5

Strona 175 - Disable/Enable Code 11

Scanning FeaturesProduct Reference Guide 2-19Laser Pointer Control — continuedSTARTDURATION BAR CODE2 Seconds2.5 SecondsEND

Strona 176 - Code 11 — continued

Product Reference Guide 1-iTable of ContentsAbout This Manual ... 1-1Manual

Strona 177

General Features2-20 PowerScan® 7000 SRINOTES

Strona 178

Product Reference Guide 3-1Chapter 3Interface RelatedFeaturesAt the time of this writing, the Scanner supports the interfaces listed in Tab le 3 - 1.

Strona 179

Interface Related Features3-2 PowerScan® 7000 SRITable 3-1. Interfaces SupportedRS-232 Page Keyboard Wedge PageRS-232 Standard3-10Keyboard Wedge HaRS-

Strona 180

Product Reference Guide 3-3Table 3-2. Keyboard Wedge Interface ReferenceI/F Type PCs SupportedA PC/XT w/Alternate Key EncodingBAT, PS/2 25-286, 30-286

Strona 181 - MSI/Plessey

Interface Related Features3-4 PowerScan® 7000 SRIInterface SelectionSTARTINTERFACE BAR CODERS-232StandardRS-232Wincor-NixdorfIBM 4683Port 5BIBM 4683Po

Strona 182 - MSI/Plessey — continued

Interface SelectionProduct Reference Guide 3-5Interface Selection — cont.STARTINTERFACE BAR CODEKeyboardWedge AKeyboardWedge BKeyboardWedge CKeyboardW

Strona 183

Interface Related Features3-6 PowerScan® 7000 SRIInterface Selection — cont.STARTINTERFACE BAR CODEKeyboardWedge HKeyboardWedge IKeyboardWedge JKeyboa

Strona 184

Interface SelectionProduct Reference Guide 3-7Interface Selection — cont.STARTINTERFACE BAR CODEKeyboardWedge OKeyboardWedge PKeyboardWedge QKeyboardW

Strona 185

Interface Related Features3-8 PowerScan® 7000 SRIInterface Selection — cont.STARTINTERFACE BAR CODEKeyboardWedge UKeyboardWedge VKeyboardWedge WKeyboa

Strona 186

Interface FeaturesProduct Reference Guide 3-9Interface FeaturesGlobal Interface FeaturesSTARTSTATE BAR CODEObey HostCommandsIgnore HostCommandsHostTra

Strona 187

ii PowerScan® 7000 SRIBar/Space Polarity ... 3-34Wand Idle State ...

Strona 188

Interface Related Features3-10 PowerScan® 7000 SRIRS-232 Interface FeaturesSTARTBAUD RATE BAR CODE1200 Baud2400 Baud4800 Baud9600 Baud19200 Baud38400

Strona 189 - Standard 2 of 5

Interface FeaturesProduct Reference Guide 3-11RS-232 Interface Features — cont.STARTBAUD RATE BAR CODE57600 Baud115200 BaudEND

Strona 190 - Standard 2 of 5 — continued

Interface Related Features3-12 PowerScan® 7000 SRIRS-232 Interface Features — cont.STARTSTATE BAR CODE7 Data Bits8 Data Bits1 Stop Bit2 Stop BitsParit

Strona 191

Interface FeaturesProduct Reference Guide 3-13RS-232 Interface Features — cont.STARTSTATE BAR CODEParity = EvenParity = OddEND

Strona 192

Interface Related Features3-14 PowerScan® 7000 SRIRS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Control — The scanner transmi

Strona 193

Interface FeaturesProduct Reference Guide 3-15RS-232 Interface Features — cont.STARTSTATE BAR CODEDisableHardwareControlEnable CTS Flow ControlEnable

Strona 194

Interface Related Features3-16 PowerScan® 7000 SRIInterchar Delay = 30 msecInterchar Delay = 40 msecInterchar Delay = 50 msecInterchar Delay = 60 msec

Strona 195

Interface FeaturesProduct Reference Guide 3-17Interchar Delay = 90 msecDisableSoftware Flow ControlEnableSoftware Flow ControlENDRS-232 Interface Feat

Strona 196 - Disable/Enable PDF 417

Interface Related Features3-18 PowerScan® 7000 SRIRS-232 Interface Features — cont.Host EchoWhen enabled, this feature passes all data through the sca

Strona 197 - PDF 417 — continued

Interface FeaturesProduct Reference Guide 3-19RS-232 Interface Features — cont.STARTSTATE BAR CODEDisable Host EchoEnable Host EchoHost Echo Quiet Int

Strona 198

Product Reference Guide 1-iiiRSS Expanded 2D Component ... 5-31RSS Limited ...

Strona 199

Interface Related Features3-20 PowerScan® 7000 SRIHost Echo Quiet Interval= 40msecHost Echo Quiet Interval= 50msecHost Echo Quiet Interval= 60msecHost

Strona 200

Interface FeaturesProduct Reference Guide 3-21Beep on ASCII BELEnables/disables ability of scanner to beep (sound a good read tone) on receiving an AS

Strona 201 - Micro PDF 417

Interface Related Features3-22 PowerScan® 7000 SRIACK NAK OptionsThis enables/disables the ability of the scanner to support the RS-232 ACK/NAK protoc

Strona 202 - Micro PDF 417 — continued

Interface FeaturesProduct Reference Guide 3-23ACK NAK Options — cont.STARTSTATE BAR CODEDisable ACK NAKEnable ACK NAK forTransmissionEnable ACK NAK fo

Strona 203

Interface Related Features3-24 PowerScan® 7000 SRIRS-232 Interface Features — cont.ACK CharacterSTARTMODE BAR CODESets the ACK character from the set

Strona 204

Interface FeaturesProduct Reference Guide 3-25RS-232 Interface Features — cont.NAK CharacterSTARTMODE BAR CODESets the NAK character from the set of A

Strona 205

Interface Related Features3-26 PowerScan® 7000 SRIRS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables retry after the configurab

Strona 206

Interface FeaturesProduct Reference Guide 3-27RS-232 Interface Features — cont.ACK NAK Timeout ValueSTARTMODE BAR CODEThis item specifies the time the

Strona 207 - Product Specifications

Interface Related Features3-28 PowerScan® 7000 SRIRS-232 Interface Features — cont.ACK NAK Retry CountSTARTMODE BAR CODEThis feature sets the number o

Strona 208 - Electrical Parameters

Interface FeaturesProduct Reference Guide 3-29RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies the method the scanner will u

Strona 209 - Environmental Parameters

iv PowerScan® 7000 SRICode 11 ... 5-77Disable/Enable Code 11 ..

Strona 210 - A-4 PowerScan® 7000 SRI

Interface Related Features3-30 PowerScan® 7000 SRIRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label indicatio

Strona 211 - Cable Pinouts

Interface FeaturesProduct Reference Guide 3-31IBM-USB Interface FeaturesIBM-USB Device usageThe IBM-USB protocol allows for the scanner to be identifi

Strona 212 - Wand Emulation

Interface Related Features3-32 PowerScan® 7000 SRIIBMIBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner's ability to set

Strona 213 - 10 Position RJ

Interface FeaturesProduct Reference Guide 3-33Wand EmulationSupported SymbologiesThe Wand Emulation interface will transmit bar code data as a wand de

Strona 214

Interface Related Features3-34 PowerScan® 7000 SRIWand Emulation — cont.Bar/Space Polarity Low/High — Black will be transmitted as a low voltage level

Strona 215 - Alpha-Numeric Pad

Interface FeaturesProduct Reference Guide 3-35Wand Emulation — cont.STARTSTATE BAR CODEWand Idle State = LowWand Idle State = HighEND

Strona 216

Interface Related Features3-36 PowerScan® 7000 SRIWand Emulation — cont.Signal SpeedThe speed of the transmission can be set. This selects the width

Strona 217 - Default Settings

Interface FeaturesProduct Reference Guide 3-37Wand Emulation — cont.Transmit Leading NoiseEnables/disables the ability of scanner to generate noise tr

Strona 218 - D-2 PowerScan® 7000 SRI

Interface Related Features3-38 PowerScan® 7000 SRIWand Emulation — cont.Transmit Trailing NoiseEnables/disables ability of scanner to generate noise t

Strona 219 - Product Reference Guide D-3

Interface FeaturesProduct Reference Guide 3-39Symbology ConversionWand Emulation can convert all bar codes to a single symbology. Choices are:No Conve

Strona 220 - D-4 PowerScan® 7000 SRI

Product Reference Guide 1-1Chapter 1Getting StartedThe PowerScan® 7000 SRI (Standard Range Imager) marks a new per-formance level for handheld scanner

Strona 221 - Product Reference Guide D-5

Interface Related Features3-40 PowerScan® 7000 SRISymbology Conversion — cont.STARTSTATE BAR CODEConvert to C39Convert toC128END

Strona 222 - D-6 PowerScan® 7000 SRI

Interface FeaturesProduct Reference Guide 3-41Keyboard Wedge/USB KeyboardAs a keyboard interface, the scanner supports most popular PCs and IBM termin

Strona 223 - Product Reference Guide D-7

Interface Related Features3-42 PowerScan® 7000 SRIKeyboard Wedge/USB Keyboard — cont.STARTSTATE BAR CODEFranceGermanyItalyNorwayPortugalSpainSweden

Strona 224 - D-8 PowerScan® 7000 SRI

Interface FeaturesProduct Reference Guide 3-43Keyboard Wedge/USB Keyboard — cont.STARTSTATE BAR CODESwitzerlandJapan 106 KeyHungaryCzechSlovakiaRomani

Strona 225 - Product Reference Guide D-9

Interface Related Features3-44 PowerScan® 7000 SRIKeyboard Wedge/USB Keyboard — cont.STARTSTATE BAR CODECroatiaPolandEND

Strona 226 - D-10 PowerScan® 7000 SRI

Interface FeaturesProduct Reference Guide 3-45Keyboard Wedge/USB Keyboard — cont.Caps Lock StateSpecifies which format the scanner sends character dat

Strona 227 - Product Reference Guide D-11

Interface Related Features3-46 PowerScan® 7000 SRIKeyboard Wedge/USB Keyboard — cont.Keyboard SimulationAll PCs check the keyboard status during the p

Strona 228 - D-12 PowerScan® 7000 SRI

Interface FeaturesProduct Reference Guide 3-47Keyboard Wedge/USB Keyboard — cont.STARTSTATE BAR CODEDisableKeyboardSimulationEnableKeyboardSimulationD

Strona 229 - Product Reference Guide D-13

Interface Related Features3-48 PowerScan® 7000 SRIKeyboard Wedge/USB Keyboard — cont.Wedge Quiet IntervalQuiet Interval is the amount of time to look

Strona 230 - D-14 PowerScan® 7000 SRI

Interface FeaturesProduct Reference Guide 3-49Keyboard Wedge/USB Keyboard — cont.Intercharacter DelaySTARTMODE BAR CODEOne-half of the delay specified

Strona 231 - Key Mappings

Getting Started1-2 PowerScan® 7000 SRIManual ConventionsThe symbols listed below are used in this manual to notify the reader of key issues or proced

Strona 232 - E-2 PowerScan® 7000 SRI

Interface Related Features3-50 PowerScan® 7000 SRINOTES

Strona 233 - Product Reference Guide E-3

Product Reference Guide 4-1Chapter 4Data EditingData Editing OverviewWhen a bar code is scanned, additional information can be sent to the host comput

Strona 234 - E-4 PowerScan® 7000 SRI

Data Editing4-2 PowerScan® 7000 SRIPlease Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophisticated f

Strona 235 - Product Reference Guide E-5

Global Prefix/SuffixProduct Reference Guide 4-3Global Prefix/Suffix — continuedExample: Setting a PrefixIn this example, we’ll set a prefix for all sy

Strona 236 - E-6 PowerScan® 7000 SRI

Data Editing4-4 PowerScan® 7000 SRIGlobal Prefix/Suffix — continuedSTARTMODE BAR CODESets up to 20 characters each from the set of ASCII characters or

Strona 237 - Product Reference Guide E-7

AIM IDProduct Reference Guide 4-5AIM IDAIM label identifiers (as opposed to custom characters you select your-self as with label identifiers) can be i

Strona 238 - E-8 PowerScan® 7000 SRI

Data Editing4-6 PowerScan® 7000 SRIAIM ID — continuedSTARTSTATE BAR CODEDisable AIM IDEnable AIM IDEND

Strona 239 - Product Reference Guide E-9

Label IDProduct Reference Guide 4-7Label IDA Label ID is a customizable code of up to two ASCII characters (00-FF), used to identify a bar code (symbo

Strona 240 - E-10 PowerScan® 7000 SRI

Data Editing4-8 PowerScan® 7000 SRILabel ID — continuedSTARTOPTION BAR CODELabel IDTransmission: DisableLabel IDPosition: Before Bar Code DataLabel ID

Strona 241 - Host Commands

Label IDProduct Reference Guide 4-9Label ID — continuedSTARTOPTION BAR CODESet UPC-Aw/C128 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:

Strona 242 - F-2 PowerScan® 7000 SRI

Connecting the ScannerProduct Reference Guide 1-3Figure 1. RS-232 Serial ConnectionUSB Connection — Connect the scanner to a USB port on the termi-nal

Strona 243 - Sample Symbols

Data Editing4-10 PowerScan® 7000 SRILabel ID — continuedSTARTOPTION BAR CODESet EAN-8w/P5 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:FF

Strona 244

Label IDProduct Reference Guide 4-11Label ID — continuedSTARTOPTION BAR CODESet GTINLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: G (47 hex)Se

Strona 245 - Indications

Data Editing4-12 PowerScan® 7000 SRILabel ID — continuedSTARTOPTION BAR CODESet RSS ExpandedLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: RX(5

Strona 246 - H-2 PowerScan® 7000BT SRI

Label IDProduct Reference Guide 4-13Label ID — continuedSTARTOPTION BAR CODESetPharmacode 39Label IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: A (4

Strona 247 - Product Reference Guide H-3

Data Editing4-14 PowerScan® 7000 SRILabel ID — continuedSTARTOPTION BAR CODESetMSI/PlesseyLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:@ (40 h

Strona 248 - Error Codes

Label IDProduct Reference Guide 4-15Case ConversionThis feature can convert scanned bar code data to either all lower case or all upper case character

Strona 249

Data Editing4-16 PowerScan® 7000 SRICharacter ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pai

Strona 250 - H-6 PowerScan® 7000BT SRI

Label IDProduct Reference Guide 4-17Character Conversion — continuedSTARTMODE BAR CODECharacterConversionDEFAULT SETTING FOR THIS FEATURE:FFFFFFFFFFFF

Strona 251 - ASCII Chart

Data Editing4-18 PowerScan® 7000 SRINOTES

Strona 252

Product Reference Guide 5-1Chapter 5SymbologiesThe scanner supports the following symbologies (bar code types). Options for each symbology are include

Komentarze do niniejszej Instrukcji

Brak uwag