Datalogic DS4800 Instrukcja Użytkownika Strona 57

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 100
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 56
2KN FAMILY AND DS4800 PARAMETERS LIST
4
PARAMETER COMPLETE PATH SHC PT VALUE
DATA FORMAT / STANDARD PARAMETERS
Header String /Comms
/OutForm/Standard
/Header
6 3 Length: 0 to 128
Code Position Tx /Comms
/OutForm/Standard
/CodePosition
547 1 0 = Disable
1 = Enable
Code Direction
Identifier Enable
/Comms
/OutForm/Standard
/DirEn
508 1 0 = Disable
1 = Enable
Forward Direction
String
/Comms
/OutForm/Standard
/FwDirection
509 3 Length: 0 to 32
Reverse Direction
String
/Comms
/OutForm/Standard
/RvDirection
528 3 Length: 0 to 32
Unknown Direction
String
/Comms
/OutForm/Standard
/NoDirection
550 3 Length: 0 to 32
Motor OFF
Message
/Comms
/OutForm/Standard
/MotorOFFFail
548 1 0 = Disable
1 = Enable
Motor OFF String /Comms
/OutForm/Standard
/MotorOFFFailMsg
549 3 Length: 0 to 128
Termination String /Comms
/OutForm/Standard
/Terminator
7 3 Length: 0 to 128
Data packet
Separators
/Comms
/OutForm/Standard
/Separator
82 3 Length: 0 to 128
Info Field
Separators
/Comms
/OutForm/Standard
/InfoFieldSeparator
83 3 Length: 0 to 128
Code Field
Separators
/Comms
/OutForm/Standard
/BarCodeField
Separator
5249 3 Length: 0 to 128
Code Field Length
Setting
/Comms
/OutForm/Standard
/FieldType
45 1 1 = Fixed Length
0 = Variable Length
51
Przeglądanie stron 56