Datalogic SC6000-1200 Instrukcja Obsługi Strona 69

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 68
ALTERNATIVE CONNECTIONS REFERENCE
59
A
V
PS/PS AUX ENCODER
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS*
Signal
PWO
V
S
V
S
PSIN
+ 5V
~
~
+
-
*VS_INPUTS is connected through the 25-pin Extended I/O connector. If this connector is not used, VS_INPUTS
must be wired from one of the scanner terminals inside PWO, see the PWO Reference Manual for details.
Figure 45 - PNP Command Input Using System Power
V
PS/PS AUX ENCODER
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS*
Signal
PWO
V
S
V
S
PSIN
+ 5V
~
~
+
-
*VS_INPUTS is connected through the 25-pin Extended I/O connector. If this connector is not used, VS_INPUTS
must be wired from one of the scanner terminals inside PWO, see the PWO Reference Manual for details.
Figure 46 - NPN Command Input Using System Power
Przeglądanie stron 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 75 76 77

Komentarze do niniejszej Instrukcji

Brak uwag