Datalogic STAR Modem Dokumentacja Strona 173

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 197
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 172
TECHNICAL FEATURES
6
GRYPHON™ Dx30/Mx30 READER DATA ENTRY
Beeper¹
LED Good Read Spot Meaning
one beep²
ON ON Correct read of a code in normal mode
H L long TX buffer full (when FIFO is enabled) or TX
error between Gryphon™ Mx30 and
OM-Gryphon™
H long ON ON Successful advanced format concatenation
H H H Timeout expired – operation not completed
H H long Error in advanced data formatting
OFF OFF Ready to read a code
GRYPHON™ Mx30 POWER
Beeper LED Meaning
10 short H 10 short blinks Low Battery
GRYPHON™ Mx30 BIND, JOIN, COPY COMMANDS
Beeper¹
LED Meaning
Blinking Command accepted; reader ready to be inserted into
the cradle
L Success
H L long tones Failure
¹ Only the Beeper Intensity command can modify these signals.
² The data entry good read tone is user-configurable with
all the Beeper commands
in the Reading Parameters section.
For Mx30 series readers, normally this results in two beeps; the first indicates that
the reader has decoded the code, the second indicates whether OM-Gryphon™
has received the data. See also par. 5.7.3.
163
Przeglądanie stron 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 196 197

Komentarze do niniejszej Instrukcji

Brak uwag