MATRIX 210™ HOST MODE PROGRAMMING
40
4
PARAMETER TYPE SEL STRING DATA
Check Digit Status 1 1 <ESC> I e 0 = Disabled
1 = Enabled Mod 10
2 = Enabled Mod 10 + Mod11
3 = Enabled 2 Mod 10
Check Digit TX 1 1 <ESC> I f 0 = Disabled
1 = Enabled
Narrow Margins 1 1 <ESC> I g 0 = Disabled
1 = Enabled
STANDARD 2 OF 5
Status 1 1 <ESC> H z 0 = Disabled
1 = Enabled
Check Digit Status 1 1 <ESC> I a 0 = Disabled
1 = Enabled
Check Digit TX 1 1 <ESC> I b 0 = Disabled
1 = Enabled
Narrow Margins 1 1 <ESC> I c 0 = Disabled
1 = Enabled
MATRIX 2 OF 5
Status 1 1 <ESC> H s 0 = Disabled
1 = Enabled
Check Digit Status 1 1 <ESC> H t 0 = Disabled
1 = Enabled
Check Digit TX 1 1 <ESC> H u 0 = Disabled
1 = Enabled
Narrow Margins 1 1 <ESC> H v 0 = Disabled
1 = Enabled
UPC/EAN FAMILY
Status 1 1 <ESC> H d 0 = Disabled
1 = Enabled
ADDON 2 and 5 Status 1 1 <ESC> H e 0 = Disabled
1 = Enabled
2 = Enabled (+AddOn 2 No Quiet Zone)
Expand UPC E0-E1
symbols
1 1 <ESC> H f 0 = Disabled
1 = Enabled
Narrow Margins 1 1 <ESC> H g 0 = Disabled
1 = Enabled
Margin Size (%)
(% of narrow module
size)
1 1 <ESC> H w 0 = 200
1 = 250
2 = 300
3 = 350
4 = 400
5 = 450
CODABAR
Status 1 1 <ESC> H i 0 = Disabled
1 = Enabled
Narrow Margins 1 1 <ESC> H j 0 = Disabled
1 = Enabled
Check Digit Status 1 1 <ESC> H h 0 = Disabled
1 = Enabled
Check Digit TX 1 1 <ESC> H k 0 = Disabled
1 = Enabled