Matrix-2000™ Reference Manual
1
STEP 5 – CONFIGURATION USING AUTOLEARNING WIZARD
1. Select the Autolearning Wizard button from the Main menu.
2. Place the desired code in front of the reader at the correct reading distance (depending
on the model, see the Reading Features table in par. 7.1).
3. Press the "Positioning" button. The reader continuously acquires images and gives visual
feedback in the view image window to indicate when the code is centered with respect to
the reader's FOV. Move the reader (or code) to center it. Press the Positioning button
again to stop positioning.
4. Select a Calibration Mode choice and press the "Calibrate" button.
5
4
3
Autolearning
Result