
147
Data Matrix
Defaults
Scanner
Type
Code
Parameter
Description
I.D.#
Accept.
Input
Min
Max
Factory
2D Imager
Enter 1 for On and 0 for Off
Data Matrix
Enable
Enables/ disables the Data
Matrix symbology.
0B00 On or Off Off On On √
Data Matrix
Minimum
Set the minimum bar code
label length to be less than
or equal to maximum label
length.
0B20 1-1500 1 1 1 √
Data Matrix
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0B21 1-1500 1 1500 1500 √
Data Matrix
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
0B23
Any
single
ASCII
character
(00 = Off)
‘V’ ‘V’ ‘V’ √
Komentarze do niniejszej Instrukcji