1 DEFAULT
UK
Read the RESTORE DEFAULT.
I Leggere il codice che ripristina i default.
F Lecture du code de configuration par défaut.
D Lesen Sie den Restore Default Code, um die
Werkseinstellung wieder herzustellen.
E Lea el código de reastauración predefinida.
RESTORE DEFAULT
Ì$+$*oÎ
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled;
DATA FORMAT: code identifier disabled, no field adjustment,
code length not transmitted, no header, terminator = CR-LF.
character replacement disabled
RS232 Nixdorf DEFAULT SETTINGS
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking
hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec.,
ack/nack disabled, FIFO disabled, serial trigger lock disabled;
DATA FORMAT: code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled
RS232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 2 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled;
DATA FORMAT: code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled
RS232 ICL DEFAULT SETTINGS
9600 baud, parity even, 8 data bits, 1 stop bit, handshaking
RTS always on, delay disabled, rx timeout 9.9 sec., ack/nack
disabled, FIFO enabled, serial trigger lock disabled;
DATA FORMAT: code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled