Strona 1 - MATRIX 200™

MATRIX 200™Reference Manual

Strona 2

GENERAL VIEW Matrix 200™ 3 5 4 1 3 2 1 Figure A 1 2 3 5Mounting Holes (4) "POWER ON" LED Device Class Labels Reading Window

Strona 3 - CONTENTS

MATRIX 200™ REFERENCE MANUAL 8 For device replacement it is necessary to send the previously saved configuration (both Configuration and Environmenta

Strona 4

SOFTWARE CONFIGURATION 88.4.3 Calibration VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the acquisition paramete

Strona 5

MATRIX 200™ REFERENCE MANUAL 8 The following examples show some of the typical conditions occurring during the installation: Under-exposure: To corr

Strona 6 - REFERENCES

SOFTWARE CONFIGURATION 8Over-exposure: To correct this result it is recommended to change the following parameters in their order of appearance: 1. d

Strona 7 - COMPLIANCE

MATRIX 200™ REFERENCE MANUAL 8 Moving code out of the Field of View: To correct this result and have the code completely visible in F.O.V., it is pos

Strona 8 - HANDLING

SOFTWARE CONFIGURATION 88.4.4 Multi Image Acquisition Settings When controlled variable conditions occur in the application, Multiple Image Acquisit

Strona 9

MATRIX 200™ REFERENCE MANUAL 8 8.4.6 Region Of Interest Windowing In order to satisfy very high throughput applications, higher frame rates can be

Strona 10 - GENERAL VIEW

SOFTWARE CONFIGURATION 88.4.7 Direct Part Marking Applications Decoding Method: Direct Marking For DataMatrix and QR code the Decoding Method param

Strona 11 - 1 RAPID CONFIGURATION

MATRIX 200™ REFERENCE MANUAL 8 Image Filter Sets the filter to be applied to the image before being processed. This parameter can be used to success

Strona 12

SOFTWARE CONFIGURATION 88.5 IMAGE CAPTURE AND DECODING By using the Capture Image and Decode Last Image functions from the VisiSet™ Main menu, you c

Strona 13 - RAPID CONFIGURATION

RAPID CONFIGURATION 11 RAPID CONFIGURATION STEP 1 – CONNECT THE SYSTEM 25-Pin Models To connect the system in a Stand Alone configuration, you nee

Strona 14 - USB Models

Matrix 400™ Reference Manual 5 9 MAINTENANCE 9.1 CLEANING Clean the reading window (see Figure A, 1) periodically for continued correct operation

Strona 15

TROUBLESHOOTING 1010 TROUBLESHOOTING 10.1 GENERAL GUIDELINES • When wiring the device, pay careful attention to the signal name (acronym) on the

Strona 16

MATRIX 200™ REFERENCE MANUAL 10 TROUBLESHOOTING GUIDE Problem Suggestion One Shot or Phase Mode using serial trigger source: the ”TRIGGER” LED is not

Strona 17 - STEP 3 – AIM THE READER

TROUBLESHOOTING 10TROUBLESHOOTING GUIDE Problem Suggestion Communication: data transferred to the host are incorrect, corrupted or incomplete. • Are

Strona 18

MATRIX 200™ REFERENCE MANUAL 104 11 11 TECHNICAL FEATURES ELECTRICAL FEATURES Matrix 200 21x-x0x models Matrix 200 21x-x2x models Power Suppl

Strona 19

TECHNICAL FEATURES 11SOFTWARE FEATURES Readable Code Symbologies 1-D and stacked 2-D POSTAL • PDF417 Standard and Micro PDF417 • Code 128 (EAN 12

Strona 20

GLOSSARY AIM (Association for Automatic Identification and Mobility): AIM Global is the international trade association representing automatic iden

Strona 21

Depth of Field The difference between the minimum and the maximum distance of the object in the field of view that appears to be in focus. Diffused

Strona 22

ISO (International Organization for Standardization): A network of the national standards institutes of several countries producing world-wide indust

Strona 23 - STEP 7 – TEST MODE

INDEX 2 25-Pin Connector; 51 25-Pin Direct Connections; 51 A Accessories; 25 Application Examples; 25 Auxiliary RS232 Interface; 44; 62 C Calibratio

Strona 24 - Code Quality Verification

MATRIX 200™ REFERENCE MANUAL 1 CBX100/CBX500 Pinout for Matrix 200™ 25-Pin Models The table below gives the pinout of the CBX100/CBX500 terminal blo

Strona 25 - 2 INTRODUCTION

DECLARATION OF CONFORMITY 08Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that

Strona 26

www.automation.datalogic.com

Strona 27 - INTRODUCTION

RAPID CONFIGURATION 125-Pin Connector Pinout for Matrix 200™ 25-Pin Models The table below gives the pinout of the 25-pin male D-sub connector for co

Strona 28

MATRIX 200™ REFERENCE MANUAL 1 USB Models NOTE Before connecting the reader to the USB Port, Install the USB Virtual COM Port Driver from the Suppo

Strona 29 - 2.3 ID-NET™

RAPID CONFIGURATION 16. From the "Advanced Settings for COMx" dialog: • Expand the "COM Port Number" menu and select a new COM P

Strona 30

MATRIX 200™ REFERENCE MANUAL 1 STEP 2 – MOUNT AND POSITION THE READER 1. To mount the Matrix 200™, use the mounting brackets to obtain the most sui

Strona 31

RAPID CONFIGURATION 13. Refer to the Reading Features table in chp. 7 to determine the distance your reader should be positioned at. NOTE Rapid Co

Strona 32 - 2.4.1 X-PRESS™ Functions

MATRIX 200™ REFERENCE MANUAL 1 STEP 4 – X-PRESS™ CONFIGURATION Once Matrix 200™ is positioned with respect to the code (step 3), you can configure i

Strona 33 - Aim/Locate (Function 2)

RAPID CONFIGURATION 1STEP 5 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several important

Strona 34 - 2.5 MODEL DESCRIPTION

Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Matrix 200™ Reference Manual Ed.:

Strona 35 - 2.7 APPLICATION EXAMPLES

MATRIX 200™ REFERENCE MANUAL 1 Set the communication parameters from the "Options" menu. Then select "Connect", the following win

Strona 36

RAPID CONFIGURATION 12. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the view image

Strona 37

MATRIX 200™ REFERENCE MANUAL 1 4. Select a Code Setting Mode choice and press the "Code Setting" button. The Autolearning Result section

Strona 38 - 3 INSTALLATION

RAPID CONFIGURATION 1STEP 7 – TEST MODE Use a code suitable to your application to test the reading performance of the system. Alternatively, you can

Strona 39 - 3.2 MECHANICAL DIMENSIONS

MATRIX 200™ REFERENCE MANUAL 1 ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the VisiSet™ Help On-Li

Strona 40

INTRODUCTION 22 INTRODUCTION 2.1 PRODUCT DESCRIPTION Matrix 200™ is the new Datalogic 2D reader offering excellent reading performance, ultra compa

Strona 41 - INSTALLATION

MATRIX 200™ REFERENCE MANUAL 2 Matrix 200™ has been developed for use in numerous industries like: Electronics:  PCB Board Tracking  Electronics

Strona 42

INTRODUCTION 2Some of the main features of this reader are given below: • Ultra Compact Dimensions • Direct and 90° window models for smart mounting

Strona 43 - CBX ELECTRICAL CONNECTIONS

MATRIX 200™ REFERENCE MANUAL 2 2.2 INDICATORS AND KEYPAD BUTTON 2 3 4 5 6 1 7 Figure 16 - Indicators The following LED indicators are located

Strona 44 - 4.2 MAIN SERIAL INTERFACE

INTRODUCTION 22.3 ID-NET™ The ID-NET™ network is a built-in high-speed interface dedicated for high-speed reader interconnection. ID-NET™ is in addit

Strona 45 - 4.2.1 RS232 Interface

CONTENTS REFERENCES ...vi Conventions...

Strona 46 - CBX100/500 Function

MATRIX 200™ REFERENCE MANUAL 2  ID-NET™ M/S Multidata: Multiple stations – single reader ID-NET™ interface allows connection of readers reading

Strona 47

INTRODUCTION 27. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data Collection parameters, etc.]. 8. If using the

Strona 48

MATRIX 200™ REFERENCE MANUAL 2 2.4 X-PRESS™ HUMAN MACHINE INTERFACE X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of i

Strona 49 - 4.3.1 ID-NET™ Cables

INTRODUCTION 2 green green yellow yellow red green green yellow yellow red green green yellow yellow red  Release button to enter Setup Mode Rel

Strona 50 - 4.3.2 ID-NET™ Response Time

MATRIX 200™ REFERENCE MANUAL 2 Setup (Function 3) Once entered, the imager automatically performs Image Acquisition parameter calibration for the sp

Strona 51

INTRODUCTION 22.6 ACCESSORIES The following accessories can be used with the Matrix 200™ reader. Order No. Accessory Description 93A301067 CBX100

Strona 52

MATRIX 200™ REFERENCE MANUAL 2 Matrix 200™ assures the reading of deformed and / or overprinted codes, even though damaged or printed on high reflect

Strona 53

INTRODUCTION 2 Figure 22 - Dot Peening Marking on Metal Surface with Multi-dot per Code Element Figure 23 - Directly Marked Dot Matrix Code Chara

Strona 54

MATRIX 200™ REFERENCE MANUAL 3 3 INSTALLATION 3.1 PACKAGE CONTENTS Verify that the Matrix 200™ reader and all the parts supplied with the equipmen

Strona 55 - Function

INSTALLATION 33.2 MECHANICAL DIMENSIONS Matrix 200™ can be installed to operate in different positions. The four screw holes (M3 x 4) on the body of

Strona 56 - PH-1 Photocell (PNP)

4.3.3 ID-NET™ Network Termination...44 4.4 Auxiliary RS232 Interface

Strona 57 - Input Device

MATRIX 200™ REFERENCE MANUAL 3 6439[1.54][2.52]2[0.08]90°19[0.75]12.5[0.49] 25 [0.98] 19[0.75]60°30°12.5[0.49] 25 [0.98] 60°30°Ø 6.2 n°3n°4 SLOT 3.1

Strona 58

INSTALLATION 33.3 MOUNTING AND POSITIONING MATRIX 200™ Using the Matrix 200™ mounting brackets you can obtain rotation on the various axes of the re

Strona 59 - Output Device

MATRIX 200™ REFERENCE MANUAL 3 Matrix 200™ is able to decode code labels at a variety of angles, however significant angular distortion may degrade r

Strona 60 - 4.7 USER INTERFACE - HOST

CBX ELECTRICAL CONNECTIONS 44 CBX ELECTRICAL CONNECTIONS All Matrix 200™ 25-pin models can be directly connected to a CBX connection box. We recom

Strona 61 - 5.1 25-PIN CONNECTOR

MATRIX 200™ REFERENCE MANUAL 4 NOTE To avoid electromagnetic interference when the reader is connected to a CBX connection box, verify the jumper po

Strona 62 - 5.3 MAIN SERIAL INTERFACE

CBX ELECTRICAL CONNECTIONS 44.2.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave connections. When

Strona 63 - 5.3.1 RS232 Interface

MATRIX 200™ REFERENCE MANUAL 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communica

Strona 64 - Matrix 200™

CBX ELECTRICAL CONNECTIONS 44.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the mor

Strona 65 - Pin Name Function

MATRIX 200™ REFERENCE MANUAL 4 Figure 43 - Matrix 200™ Multidrop Connection to a Multiplexer 38

Strona 66 - CAUTION

CBX ELECTRICAL CONNECTIONS 44.3 ID-NET™ INTERFACE CBX100/500 Function Shield Network Cable Shield ID+ ID-NET™ network + ID- ID-NET™ network - REF

Strona 67 - 5.4.1 ID-NET™ Cables

11 TECHNICAL FEATURES...104 GLOSSARY...

Strona 68 - 5.4.2 ID-NET™ Response Time

MATRIX 200™ REFERENCE MANUAL 4 4.3.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is defined

Strona 69

CBX ELECTRICAL CONNECTIONS 4 Figure 45 – ID-NET™ Network Connections with isolated power blocks 41

Strona 70

MATRIX 200™ REFERENCE MANUAL 4 Figure 46 - ID-NET™ Network Connections with Common Power Branch Network 42

Strona 71

CBX ELECTRICAL CONNECTIONS 4 Figure 47 – ID-NET™ Network Connections with Common Power Star Network 43

Strona 72

MATRIX 200™ REFERENCE MANUAL 4 4.3.3 ID-NET™ Network Termination The network must be properly terminated in the first and last reader of the networ

Strona 73 - 5.6 INPUTS

CBX ELECTRICAL CONNECTIONS 44.5 INPUTS There are two optocoupled polarity insensitive inputs available on the reader: Input 1 (External Trigger) and

Strona 74

MATRIX 200™ REFERENCE MANUAL 4 EXTERNAL TRIGGER INPUT CONNECTIONS USING MATRIX 200™ POWER CAUTION Power is available directly to the Input Device,

Strona 75

CBX ELECTRICAL CONNECTIONS 4 CBX100/500 Function +V Power Source - Inputs I2A Input 2 A (polarity insensitive) I2B Input 2 B (polarity insensitive

Strona 76 - 5.7 OUTPUTS

MATRIX 200™ REFERENCE MANUAL 4 Pulled up to External Input Device Power Input Signal Input Device Figure 55 - NPN Input 2 Using External Power 4.

Strona 77

CBX ELECTRICAL CONNECTIONS 4OUTPUT CONNECTIONS USING MATRIX 200™ POWER CAUTION Power is available directly to the Output Device, independently from

Strona 78 - 5.8 USER INTERFACE

REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix 200™ reader. "Reader&quo

Strona 79 - 6 TYPICAL LAYOUTS

MATRIX 200™ REFERENCE MANUAL 4 4.7 USER INTERFACE - HOST The following table contains the pinout for standard RS232 PC Host interface. For other us

Strona 80

25-PIN CABLE ELECTRICAL CONNECTIONS 55 25-PIN CABLE ELECTRICAL CONNECTIONS 5.1 25-PIN CONNECTOR The Matrix 200™ reader is equipped with a 25-pin m

Strona 81 - 6.2 PASS-THROUGH

MATRIX 200™ REFERENCE MANUAL 5 5.2 POWER SUPPLY Power is supplied to the reader through the pins provided on the 25-pin connector (see Figure 61):

Strona 82 - External Trigger

25-PIN CABLE ELECTRICAL CONNECTIONS 55.3.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave connectio

Strona 83

MATRIX 200™ REFERENCE MANUAL 5 5.3.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communica

Strona 84 - Fieldbus Interface

25-PIN CABLE ELECTRICAL CONNECTIONS 55.3.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend usin

Strona 85 - 6.4 RS232 MASTER/SLAVE

MATRIX 200™ REFERENCE MANUAL 5 The figure below shows a multidrop configuration with Matrix 200™ readers connected to a Multiplexer. CAUTION This i

Strona 86 - 6.5 MULTIPLEXER

25-PIN CABLE ELECTRICAL CONNECTIONS 55.4 ID-NET™ INTERFACE Pin Name Function 23 ID+ ID-NET™ network + 24 ID- ID-NET™ network - 7 GND Ground 5.4.1

Strona 87 - TYPICAL LAYOUTS

MATRIX 200™ REFERENCE MANUAL 5 5.4.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is define

Strona 88 - 7 READING FEATURES

25-PIN CABLE ELECTRICAL CONNECTIONS 5 Figure 69 – ID-NET™ Network Connections with isolated power blocks 59

Strona 89 - READING FEATURES

COMPLIANCE For installation, use and maintenance it is not necessary to open the reader. EMC COMPLIANCE In order to meet the EMC requirements: •

Strona 90 - CAUTION:

MATRIX 200™ REFERENCE MANUAL 5 Figure 70 - ID-NET™ Network Connections with Common Power Branch Network 60

Strona 91 - 8 SOFTWARE CONFIGURATION

25-PIN CABLE ELECTRICAL CONNECTIONS 5 Figure 71 – ID-NET™ Network Connections with Common Power Star Network 61

Strona 92 - 8.3 STARTUP

MATRIX 200™ REFERENCE MANUAL 5 5.4.3 ID-NET™ Network Termination The network must be properly terminated by a 120 Ohm resistor at the first and las

Strona 93 - 8.3.1 VisiSet™ Options

25-PIN CABLE ELECTRICAL CONNECTIONS 55.6 INPUTS There are two optocoupled polarity insensitive inputs available on the 25-pin connector of the reader

Strona 94

MATRIX 200™ REFERENCE MANUAL 5 EXTERNAL TRIGGER INPUT PNP PH-1 VdcGNDI1AI1B PNP PH-1 wires Matrix 200™ 18197(brown) +10-30 Vdc (black) NO (blue)

Strona 95 - 8.4 CONFIGURATION

25-PIN CABLE ELECTRICAL CONNECTIONS 5 Matrix 200™ EXTERNAL TRIGGER Vext 30 Vdc max.1819Signal VVCC ~ ~ + -I1AI1B Figure 77 - NPN External Trigger Us

Strona 96

MATRIX 200™ REFERENCE MANUAL 5 INPUT 2 CONNECTIONS USING EXTERNAL POWER Matrix 200™ INPUT DEVICE Vext 30 Vdc max.I2A 610I2B VCC ~ ~ + -VSignal Fi

Strona 97

25-PIN CABLE ELECTRICAL CONNECTIONS 5The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deac

Strona 98

MATRIX 200™ REFERENCE MANUAL 5 5.8 USER INTERFACE The following table contains the pinout for standard RS232 PC Host interface. For other user inter

Strona 99

TYPICAL LAYOUTS 66 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. However, they also require the correct setu

Strona 100 - MATRIX 200™ REFERENCE MANUAL

HANDLING The Matrix 200™ is designed to be used in an industrial environment and is built to withstand vibration and shock when correctly installed

Strona 101 - 8.4.3 Calibration

MATRIX 200™ REFERENCE MANUAL 6 In this layout a single scanner functions as a Slave node on a Fieldbus network. The data is transmitted to the Host t

Strona 102

TYPICAL LAYOUTS 66.2 PASS-THROUGH Pass-through mode allows two or more devices to be connected to a single external serial interface. Each reader tr

Strona 103 - Exposure Time

MATRIX 200™ REFERENCE MANUAL 6 6.3 ID-NET™ The ID-NET™ connection is used to collect data from several readers to build a multi-point or a multi-sid

Strona 104

TYPICAL LAYOUTS 6For a Master/Slave Multidata layout each reader has its own reading phase independent from the others; each single message is sent fr

Strona 105 - Readable

MATRIX 200™ REFERENCE MANUAL 6 Alternatively, the Master scanner can communicate to the Host as a Slave node on a Fieldbus network. This requires usi

Strona 106

TYPICAL LAYOUTS 66.4 RS232 MASTER/SLAVE NOTE This interface is provided for backward compatibility. We recommend using the more efficient ID-NET™ ne

Strona 107 - SOFTWARE CONFIGURATION

MATRIX 200™ REFERENCE MANUAL 6 6.5 MULTIPLEXER NOTE This interface is provided for backward compatibility. We recommend using the more efficient ID

Strona 108 - Image Filter

TYPICAL LAYOUTS 66.6 USB CONNECTION (MATRIX 200 XXX-X2X MODELS ONLY) For Matrix 200 XXX-020 models, the USB connection is possible in two different

Strona 109 - 8.6 STATISTICS

MATRIX 200™ REFERENCE MANUAL 78 7 7 READING FEATURES Reading Distance (3) mm (in) MODELS Focus Distance mm (in) Field of View (1) mm (in) PPI(2)

Strona 110 - 9 MAINTENANCE

READING FEATURES 77.1 MAXIMUM LINE SPEED CALCULATION The Exposure Time (or Shutter) parameter defines the time during which the image will be expos

Strona 111 - 10 TROUBLESHOOTING

• do not weld the reader into position which can cause electrostatic, heat or reading window damage. • do not spray paint near the reader whic

Strona 112

MATRIX 200™ REFERENCE MANUAL 7 The Internal Lighting Mode parameter allows to set the operating mode of the internal lighting system. The possible v

Strona 113

SOFTWARE CONFIGURATION 88 SOFTWARE CONFIGURATION Software configuration of your Matrix 200™ for static reading or simple code reading applications c

Strona 114 - 11 TECHNICAL FEATURES

MATRIX 200™ REFERENCE MANUAL 8 8.3 STARTUP After completing the mechanical and electrical connections to Matrix 200™, you can begin software configu

Strona 115 - USER INTERFACE

SOFTWARE CONFIGURATION 88.3.1 VisiSet™ Options The Options item from the VisiSet™ menu (see Figure 96) presents a window allowing you to configure:

Strona 116 - GLOSSARY

MATRIX 200™ REFERENCE MANUAL 8 Figure 99 - Options – Communication 84

Strona 117

SOFTWARE CONFIGURATION 88.4 CONFIGURATION Once connected to Matrix 200™ as described in par. 8.3, you can modify the configuration parameters as foll

Strona 118

MATRIX 200™ REFERENCE MANUAL 8 8.4.1 Edit Reader Parameters The Parameter Setup window displays the configuration parameters grouped in a series of

Strona 119

SOFTWARE CONFIGURATION 8Parameters to verify/modify:  Operating Mode Sets the parameters which customize the reader operating mode starting from th

Strona 120 - DECLARATION OF CONFORMITY

MATRIX 200™ REFERENCE MANUAL 8 When all the configuration parameters are set correctly, save them to the Matrix 200™ reader by pressing the Send butt

Strona 121

SOFTWARE CONFIGURATION 8Environmental Parameters regard the device Identity and Position in a Network (ID-NET™, Master/Slave RS232, MUX 32) and are no