Batch Features ENTER/EXIT PROGRAMMING MODE
268
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
BATCH FEATURES
Batch Mode
This option specifies whether to store labels in the handheld while disconnected from the base.
Options are as follows:
Disabled — The handheld will not store/batch labels.
Automatic — The handheld will store labels to RAM when the handheld goes out of
range and is disconnected from the re
mote device.
Manual — The handheld will always store labels to F
lash
memory. The user must manu-
ally send the stored labels to the remote device using a special "batch send"
label.
DEFAULT
Batch Mode = Disabled
Batch Mode = Automatic
Batch Mode = Manual
Send Batch
Use this barcode to initiate sending of labels stored in batch memory.
Send Batch
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction
with this barcode.