Datalogic AL5010 Informacje Techniczne Strona 119

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 118
AccuLazr™ AL5010 Product Line Manual Maintenance 111
Cleaning the Tachometer
If your application uses the tachometer option for tracking purposes, be sure
to clean the tachometer wheels periodically as outlined below.
1. Turn off the product transport.
2. Turn off the reader’s lasers.
3. Using a clean, soft cloth, wipe the wheels of the tachometer clean using
a mild detergent solution.
4. Before restarting the system, be sure the tachometer is making good
contact with the product transport.
5. Verify tachometer operation.
Tighten Mounting Hardware
1. Check all reader mounting hardware.
Tighten as necessary. Do not over-tighten.
Be sure not to disturb the reader’s alignment as it relates to the product
transport.
2. Check the mounting hardware of the photoeye and tachometer (if these
options are being used). Tighten as necessary. Do not over-tighten.
Checking Interface Module Connections
All wiring connections are typically made to an interface module.
(See Chapter 3, Installation.)
1. Check all cord grips.
Tighten as necessary. Do not over-tighten.
2. If a cord seems loose, also check the wiring connections to the terminal
blocks. Tighten as necessary. Do not over-tighten.
3. Check all cabling/conduit for signs of wear/damage.
Repair/replace any damaged cable connections as necessary.
07-AL5010_Maintenance_R20.doc Accu-Sort Systems, Inc.
Przeglądanie stron 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 239 240

Komentarze do niniejszej Instrukcji

Brak uwag