C-BOX 100
14
3
3 TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
Supply voltage 10 to 30 Vdc*
Power consumption 0.5 W + scanner power consumption
(see related manual)
Max current consumption
(short circuit protection on 25-pin connector)
2 to 2.5 A
USER INTERFACE
LED indicators Power on LED (green)
Power polarity error LED (red)
PHYSICAL FEATURES
Mechanical dimensions 167 x 115 x 40 mm (6.57 x 4.53 x 1.57 in.)
Weight about 320 g. (11.29 oz.)
ENVIRONMENTAL FEATURES
Operating temperature
-10° to 50
°C (+14° to 122 °F)
Storage temperature
-20° to 70
°C (-4° to 158 °F)
Humidity max. 90% non condensing
Vibration resistance IEC 68-2-6 test FC 1.5 mm;
10 to 55 Hz; 2 hours on each axis
Shock resistance IEC 68-2-27 test EA 30G;
11 ms; 3 shocks on each axis
Protection Class IP64
(when correctly connected to the scanner)
* for further details about minimum/maximum supply voltage refer to the manual of the
connected scanner, since the minimum supply voltage required may be >10.
NOTE
The features given are typical at a 25
°
C ambient temperature (if not
otherwise indicated).